Rewiring edinburgh
Spread the love

Sharing is caring!

Rewiring board in Edinburgh :

For the solar consumer unit, which you have temporarily repurposed as a sight Board, you’ve now disconnected the solar feed from the loft. The violators are both turned off, so there’s no back feed coming down, and then they’ve just set up this temporary 13 amp double socket on the 16 amp breaker Here. So that they’ve got site power because they’ve got a transformer with a vacuum and a chasing machine here. That they’ve hired, so that’s going to help speed things up. So you’ll tour yourself around. They just you’ve got a going around marking all the boxes Up. So they’re doing 120 to the top of the switch box and what the customer wanted in line with building regulations for new properties. They don’t have to because it’s a familiar build, but as it’s a full Rewiring Edinburgh, it just makes sense to do it. They were doing a new build anyway, so they’ve got a pendant light in the switch by the door and four double sockets.

Rewiring edinburgh

Rewiring edinburgh , one in each corner here is a drawing of the property, so you’ve got a floor plan and what you’ve done is you’ve made a circuit schedule according to what you think they will need to do in terms of circuits. They’re going to do radials because, as you know, you’re not a big fan of ring circuits. You think there are too many possibilities for problems with them. So they’re going sort of European style, basically downstairs two radials, one for the dining room, one for the living room, and then one for the family room and Hallway. They will do a ring just for the kitchen in the utility room.

Because they will need much more power there than upstairs, they’re doing a radial for bedrooms two and three and another radial for the bedroom. One and four, and the hallway lighting Circuits will have one upstairs and one downstairs. The one upstairs, they’re doing a cooker circuit as well for the kitchen.

Electricity consumer in Edinburgh :

They’ve got a feed to the garage, which will be reused that’s that armored cable coming out of the Rewiring Edinburgh consumer unit. They’re just going to re-terminate that nicely because that’s relatively new, and then they’ve got a circuit for an EV charger which they’re going to put in which will go on the surface they’ll go up through the floorboards or the loft. Then clip it on the surface on the outside and terminate it into a junction box at the moment. Because they don’t have an EV, they wanted to just future-proof things so that they’ve got potential for an EV without having to take floorboards up and mess around with the Walls.

So you’ll show you around this dining room area, so they’ve got two double sockets. There is one double socket there; they’re going to have a two gang switch here downlights in the ceiling switch to a more comprehensive angle view. So you can see two gang switches here, four or six downlights, still determining precisely. By the way, this is an Artex ceiling; they had an asbestos survey done a week ago, and they’re waiting for the results. Whether this is this ceiling contains asbestos or not, they’re not going to touch it until they get the results from the lab for the asbestos survey. If there is asbestos, then they’ll have to rethink the ceiling a little bit or take some extra precautions to ensure that it’s safe for us to cut holes in the ceiling.